• CT PT Exciting Characteristic Curve Test Analyzer
  • CT PT Exciting Characteristic Curve Test Analyzer
  • CT PT Exciting Characteristic Curve Test Analyzer
  • CT PT Exciting Characteristic Curve Test Analyzer
  • CT PT Exciting Characteristic Curve Test Analyzer

CT PT Exciting Characteristic Curve Test Analyzer

Application: High Voltage Test equipment
Power: Electricity
Certification: CE, CCC
Voltage Output: 220V
Current Output: 10A
Thermocouple (TC): S
Samples:
US$ 2200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
HFHG-8225E
Resistance-Temperature Detector (RTD)
Cu50(ITS)
LCD Display
With LCD Display
Customized
Customized
Power Supply
AC220V, 50~60Hz
Single Machine Output Voltage of Excitat
2500V
Excitation Output Current
20A
Single Machine Output Current of Transf
0~1000A
Transport Package
Wooden Case with Foam Inside, No Fumigation,Not in
Trademark
Hengfeng
Origin
China
Production Capacity
500/Year

Product Description

                                                   CT PT Exciting Characteristic Curve Test Analyzer 

CT PT Exciting Characteristic Curve Test Analyzer

Product introduction
HFHG-8225E is portable analyzer designed for analyzing current transformers and voltage transformers of protection or measurement use, which is suitable for laboratory and on-site test.


Features
1. Full-featured, not only satisfy the test requirements of various CTs (include TP class), such as the excitation characteristics (i.e., volt-ampere characteristics), ratio, polarity, secondary winding resistance, secondary burden, ratio error and phase displacement, but can also be used for the tests of various PTs, including excitation characteristics of the electromagnetic unit, ratio, polarity, secondary winding resistance, ratio error and phase displacement.
2. Automatically give CT, VT parameters, including knee point voltage / current, 10% error curve, the accuracy limit factor (ALF), instrument security factor (FS), the second time constant (Ts), remanence coefficient (Kr), saturated and unsaturated inductance etc.
3.Test meet IEC60044 GB1208 (-1) GB16847 (IEC60044-6) became etc all kinds of transformer standards, and in accordance with the transformer types and levels of automatic choose which standard test
4. Based on advanced principle of low-frequency test method that can meet the CT test on knee voltage up to 60KV.
5.Friendly interface beautiful, all Chinese graphic interface
6. The instrument can store 2000 groups of test data that won't be lost when power off. After test ended, the data can be coped to PC by USB disk for analysis and being transformed into WORD report.
7. Test is simple and convenient, one-click can complete tests of CT secondary resistance, excitation, ratio and olarity.
8. Easy to carry, because the weight is less than 9Kg


Technical specification
Usage CT, PT
Output 0~180Vrms,12Arms,36A(peak value)
Voltage measurement accuracy ±0.1%
CT Ratio Range 1~40000
accuracy ±0.05%
PT Ratio Range 1~40000
accuracy ±0.05%
Phase Range ±2min
accuracy 0.5min
DC resistance Range 0~30
accuracy 0.22
Burden Range 0~1000VA
accuracy 0.20.02VA
Power supply AC220V±10%,50Hz
Environmental Conditions   Operating temperature : -10οC~50ο,Humidity :≤90%
Weight and Dimensions Dimensions: 365 mm×290 mm×153mm,Weight<10kg

CT PT Exciting Characteristic Curve Test AnalyzerCT PT Exciting Characteristic Curve Test AnalyzerCT PT Exciting Characteristic Curve Test AnalyzerCT PT Exciting Characteristic Curve Test AnalyzerCT PT Exciting Characteristic Curve Test AnalyzerCT PT Exciting Characteristic Curve Test AnalyzerCT PT Exciting Characteristic Curve Test AnalyzerCT PT Exciting Characteristic Curve Test AnalyzerCT PT Exciting Characteristic Curve Test Analyzer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
23
Year of Establishment
2006-08-28